Product selector

CRJ

CRJ

Self Regulating Pipe Freeze Protection Cables

PW

PW

Pre-terminated Water Pipe Freeze Protection Cable

GP

GP

Self-regulating Cable for gutters & downpipes

CRJ

Self Regulating Water Pipe Freeze Protection Cable

  • Prevents water from freezing in metal and plastic pipes
  • Avoids the cost and inconvenience of burst pipes
  • Self regulating technology and recommended thermostatic control ensures lowest possible running costs

Typical Applications

  • Stables
  • Sprinkler systems

Features

  • Self regulating technology ensures that cable output will decrease as ambient temperature increases
  • Can be cut to length, terminated, T jointed and spiced on site using the BN Thermic’s termination and splice kits
  • Can be double wrapped to protect valves, flanges etc. without risk of creating hot spots
  • Fully moisture proof with full length earth braid

Controlling CRJ Self Regulating Pipe Freeze Protection cable

Although the cable’s self regulating technology ensures that cable output will decrease as ambient temperature increases, thermostatic control is still recommended. A master frost thermostat will prevent the low level of electricity consumption that would otherwise occur when the ambient temperature was above freezing point.

BN Thermic offers a choice of two frost thermostats: FST-IN and FST-EX. The FST-EX should be selected for outdoor applications or where a tamperproof device is preferred. Both thermostats have a switching capacity of 10A. Larger loads can be switched via a suitably rated contactor.

Specification

Model Volts W/m Description
CRJ-10 230 10 10W/m cable - by the metre
CRJ-25 230 25 25W/m cable - by the
CRJ-T1 Termination kit
CRJ-T5 Termination kit pack of 5
CRJ-S Splice/Tee kit
PF-L Caution labels - pack of 10
PF-T Flame Retardant fixing tape 33m x 19mm

Notes on Selection and Installation

  • Use the following tables to select the correct output and length of cable required for your application. You will notice that in most instances a straight run of cable will suffice. The table also indicates the thickness of the insulation which should cover both pipe and cable.
  • A CRJ-T1 termination kit will be required per circuit with one CRJ-S splice kit required for every splice or T
  • Secure the cable to the pipe at 200mm intervals using PF-T fixing tape
  • Plastic pipes should be wrapped in AL50 aluminium tape before installing the cable
  • Maximum circuit lengths are as follows:
    CRJ-10: 205m
    CRJ-25: 126m
  • BN Thermic PF-L warning labels should be applied to the outside of the insulation

CRJ Selection Table 1

(minimum ambient temperature -20°C)

Pipe
Dia.(mm)
Insulation Thickness(mm)
12 25 50
12 CRJ-10 Straight CRJ-10 Straight CRJ-10 Straight
25 CRJ-25 Straight CRJ-10 Straight CRJ-10 Straight
50 CRJ-25 Straight CRJ-10 Straight CRJ-10 Straight
75 CRJ-25
1.3m cable / 1m pipe
CRJ-25 Straight CRJ-10 Straight
100 CRJ-25
1.8m cable / 1m pipe
CRJ-25 Straight CRJ-25 Straight
150 CRJ-25
3m cable / 1m pipe
CRJ-25
1.4m cable / 1m pipe
CRJ-25
1.2m cable / 1m pipe

CRJ Selection Table 2

(minimum ambient temperature -20°C)

Pipe
Diameter
(mm)
Additional Cable Length (m)
Pair of
Flanges
Valve Support
12 0.23 0.10 0.10
25 0.28 0.15 0.10
50 0.30 0.30 0.15
75 0.45 0.40 0.15
100 0.60 0.50 0.20
150 0.80 0.60 0.25

 

Breaker Selection for CRJ Self Regulating Cable

Breaker Cable Length (m)
CRJ-10 CRJ-25
10A 1 to 116 1 to 60
13A 116 to 150 60 to 78
16A 150 to 205 78 to 88
30A - 88 to 126

Use type C breaker

Thermostats

FST thermostats can switch up to 116m of CRJ-10 and up to 60m of CRJ-25. Longer lengths can be switched via a suitably rated contactor. 

CRJ  Self Regulating Water Pipe Freeze Protection Cable

CRJ Self Regulating Water Pipe Freeze Protection Cable

CRJ-T Termination Kit

CRJ-T Termination Kit

CRJ-S Splice kit

CRJ-S Splice kit

CRJ Self Regulating Cable - dispensed by the metre

CRJ Self Regulating Cable - dispensed by the metre

PF-L Caution Labels

PF-L Caution Labels

PF-T Fixing Tape - Secures CRJ to pipe