Range

Models with Built-in Thermostat

Model

kW

Voltage

Built-in Thermostat

Recommended Guard

SWD-A-500

0.5

230V 1ph

Yes

SWG-1

SWD-A-1000

1.0

230V 1ph

Yes

SWG-2

SWD-A-1500

1.5

230V 1ph

Yes

SWG-3

SWD-A-2000

2.0

230V 1ph

Yes

SWG-3

SWD-A-3000

3.0

230V 1ph

Yes

SWG-4

Models without Built-in Thermostats

Model

kW

Voltage

Built-in Thermostat

Recommended Guard

SWD-U-500

0.5

230V 1ph

No

SWG-1

SWD-U-1000

1.0

230V 1ph or 400V 3ph

No

SWG-2

SWD-U-1500

1.5

230V 1ph or 400V 3ph

No

SWG-3

SWD-U-2000

2.0

230V 1ph or 400V 3ph

No

SWG-3

SWD-U-3000

3.0

230V 1ph or 400V 3ph

No

SWG-4

SWD-U-4000

4.0

230V 1ph or 400V 3ph

No

SWG-5

110V Models without Built-in Thermostat

Model

kW

Voltage

Built-in Thermostat

Recommended Guard

SWD-U-500-1

0.5

110V 1ph

No

SWG-1

SWD-U-1000-1

1.0

110V 1ph

No

SWG-2

SWD-U-1500-1

1.5

110V 1ph

No

SWG-3

Recommended Guards

Model Output of Heater
SWG-1 0.5kW
SWG-2  1.0kW
SWG-3 1.5kW and 2.0kW
SWG-4 3kW
SWG-5  4kW

               

Technical Specification

Heaters

Tube Material:   Stainless steel 1.4512
Tube diameter:  50mm
Diameter over fin: 110mm
Terminal enclosure: Reinforced glass fibre
Cable gland:  M20 x 1.5
Mounting brackets: Stainless steel 1.4512
Heating element:  Nickel chrome resistance wire wound onto technical ceramic formers
Option built-in thermostat: Adjustable range 5°C to 30°C
Ingress Protection: IP66
Height (when floor mounted): 170mm +/- 3mm
Width of heater (widest point): 110mm
Width of bracket (widest point): 130mm +/- 3mm
Guarantee: 1 year

Recommended safety guard

Material: Heavy gauge zinc plated wire with
Mounting: Clips for floor or wall mounting
Height: 240mm
Width: 240mm

Performance Data

Models with Built-in Thermostat

Model

kW

Voltage

Built-in Thermostat

Recommended Guard

SWD-A-500

0.5

230V 1ph

Yes

SWG-1

SWD-A-1000

1.0

230V 1ph

Yes

SWG-2

SWD-A-1500

1.5

230V 1ph

Yes

SWG-3

SWD-A-2000

2.0

230V 1ph

Yes

SWG-3

SWD-A-3000

3.0

230V 1ph

Yes

SWG-4

Models without Built-in Thermostats

Model

kW

Voltage

Built-in Thermostat

Recommended Guard

SWD-U-500

0.5

230V 1ph

No

SWG-1

SWD-U-1000

1.0

230V 1ph or 400V 3ph

No

SWG-2

SWD-U-1500

1.5

230V 1ph or 400V 3ph

No

SWG-3

SWD-U-2000

2.0

230V 1ph or 400V 3ph

No

SWG-3

SWD-U-3000

3.0

230V 1ph or 400V 3ph

No

SWG-4

SWD-U-4000

4.0

230V 1ph or 400V 3ph

No

SWG-5

110V Models without Built-in Thermostat

Model

kW

Voltage

Built-in Thermostat

Recommended Guard

SWD-U-500-1

0.5

110V 1ph

No

SWG-1

SWD-U-1000-1

1.0

110V 1ph

No

SWG-2

SWD-U-1500-1

1.5

110V 1ph

No

SWG-3

Recommended Guards
Model Output of Heater
SWG-1 0.5kW
SWG-2  1.0kW
SWG-3 1.5kW and 2.0kW
SWG-4 3kW
SWG-5  4kW

Physical Data

Heater kW

Length (mm)

Weight (kg)

0.5

440

3.0

1.0

640

4.8

1.5

840

6.2

2.0

1040

7.7

3.0

1440

10.9

4.0

1840

13.7

Recommended Guards

Model Length (mm)  Weight (kg)
SWG-1 450 1.0
SWG-2 650 1.5
SWG-3 1075 2.0
SWG-4 1600 3.5
SWG-5 1900 4.0

Max/Min Operating Temperatures

Orientation Maximum air temperature Minimum air temperature
Horizontal +80˚C -30˚C
Vertical (terminal box at bottom) +40˚C -30˚C
Special heaters suitable for -40˚ air temperature are  available on request

Features & Benefits

Feature Benefit
Welded stainless steel construction

Enhances corrosion resistance

Stainless steel cooling fins

Keeps heater length to a minimum

Stainless steel mounting brackets

Facilitates floor or wall mounting

Reinforced glass fibre terminal enclosure rated IP66

Heater suitable for installation in very damp environments and can be hosed down

M20 waterproof cable gland

Maintains IP66 rating

Optional built-in thermostat

Ensures economy and keeps external wiring to a minimum

Safety Guard (SWG models)

Suitable for floor or wall mounting, an SWG guard should always be used when personnel have access to a heater

 

Controls

SWD industrial finned tubular heaters should always be thermostatically controlled.  The SWD range is available with and without a built in thermostat.

Built-in Thermostat

SWD Built in thermostat

SWD Built-in
Thermostat

 

Models with the prefix SWD-A have a built-in thermostat.  The thermostat is adjustable between 5°C and 30°C by means of an external dial mounted onto the lid of the terminal enclosure.  A ‘frost protection’ setting is also provided.

 

 

Remote Mounted Thermostat

Models with the prefix SWD-U do not have a built-in thermostat.  These models can be controlled by means of a remote mounted thermostat.  When selecting the most suitable thermostat, care must be taken to ensure that the switching capacity of the thermostat is suitable for the heater in question.  Where the load of the heater exceeds the switching capacity of the thermostat or where a three phase heater is installed, a suitably rated contactor will be required.

Adjustable wall-mounted thermostat (IP54)

RST-EX IP54 Thermostat

RST-EX

Model: RST-EX

BN Thermic’s RST-EX thermostat is rated IP54 and is therefore suitable for damp conditions.  The RST-EX has an adjustable range between 5°C and 35°C and a switching capacity of 15A (230V) meaning that is can switch a 3kW 230V heater directly with larger loads and three phase loads requiring a suitably rated contactor.

 

Tamperproof wall-mounted thermostat (industrial grade)

HC-T2 Hard Case Thermostat

HC-T2
Hard Case
Thermostat

HC-D Tamperproof Tool

HC-D
Tamperproof
Tool

HC-S2 Remote Sensor

HC-S2
Remote
Sensor

BN Thermic’s famous HC-T2 Hard Case industrial and public area thermostats provide rugged tamperproof and vandal resistant control.  Hard Case thermostats require a special tool to gain access the temperature adjustment knob.  Where required the HC-T2 can be used with a remote sensor (model HC-S2).  The sensor is rated IP55 and is therefore suitable for damp conditions.

 

 

 

Selection

If you would like the experts at BN Thermic to select a suitable heating for your application, please click here to access our enquiry form.  Simply provide as much information as you have available and we will respond with a detailed proposal.

ENQUIRY FORM

SWD heaters are suitable for maintaining background heat or comfort heat in industrial buildings including damp and corrosive environments.  The heaters operate by natural convection and are therefore not well suited to buildings with a high roof.

In simple terms the output of the SWD heater or heaters must be greater than the heat losses from the building during periods of cold weather.  A small amount of heat is lost through the walls, ceilings and floors with more significant losses through windows and doors.

To estimate the heat loss from your building you may like to use our heat loss tool

HEAT CALCULATOR

The estimated heat loss figure is the absolute minimum kW output that you should consider installing.  We would suggest adding approximately 50% to this figure to allow for an acceptable warm up time in cold conditions as well as making allowances for exceptional weather conditions and possible errors in the original data used in the estimate.

Having established the minimum kW output required, select the minimum number of heaters needed to meet the kW requirement. 

Selection should be made from the following table ensuring that the selected heaters are compatible with the voltage supply.  Where possible, we would recommend heaters with a built-in thermostat although other control options are available (see control tab).

The use of SWG safety guards is always recommended where personnel can access the heaters.

 

230V Models with Built-in Thermostat

Model Number kW Voltage Built-in Thermostat Recommended Guard
SWD-A-500-2  0.5 230/1 Yes SWG-1
SWD-A-1000-2 1.0  230/1 Yes SWG-2
SWD-A-1500-2  1.5 230/1 Yes SWG-3
SWD-A-2000-2  2.0 230/1 Yes SWG-3
SWD-A-3000-2 3.0  230/1 Yes SWG-4

230V Models without Built-in Thermostat

Model Number kW Voltage Built-in Thermostat Recommended Guard
SWD-U-500-2  0.5 230/1 No SWG-1
SWD-U-1000-2 1.0  230/1 No SWG-2
SWD-U-1500-2  1.5 230/1 No SWG-3
SWD-U-2000-2  2.0 230/1 No SWG-3
SWD-U-3000-2 3.0  230/1 No SWG-4

400V Models without Built-in Thermostat

Model Number kW Voltage Built-in Thermostat Recommended Guard
SWD-U-1000-3 1.0 400/3 No SWG-2
SWD-U-1500-3 1.5 400/3 No SWG-3
SWD-U-2000-3 2.0 400/3 No SWG-3
SWD-U-3000-3 3.0 400/3 No SWG-4
SWD-U-4000-3 4.0 400/3 No SWG-5

110V Models without Built-in Thermostat

Model Number kW Voltage Built-in Thermostat Recommended Guard
SWD-U-500-1 0.5 110/1 No SWG-1
SWD-U-1000-1 1.0  110/1 No SWG-2
SWD-U-1500-1 1.5 110/1 No SWG-3

Recommended Guards

Model Output of Heater
SWG-1 0.5kW
SWG-2  1.0kW
SWG-3 1.5kW and 2.0kW
SWG-4 3kW
SWG-5  4kW

Heat Calculator

Stage 1 of 5 » Building dimensions

This calculator is provided as a quick and easy means of estimating heat loss from a building. This is a key step in determining the kW output required from a heating system.

Width m
Length m
Height m
Building dimensions

( * ) this data is compulsory

next >>>

Stage 2 of 5 » Environmental Data

Minimum outdoor temperature
(Typically -5°c in the UK)
°C
Required indoor temperature
(Typically 20°c in commercial buildings)
°C
Minimum temperature in the next room
(Input temp only if there is an adjoining room)
°C

Heat losses to an adjoining room or building are usually lower than to the outside world. To allow the calculator to take this into account we have requested the minimum expected air temperatures of an adjoining room. For a stand-along building just leave this field blank.

( * ) this data is compulsory

<<< back next >>>

Stage 3 of 5 » Construction material

U values (W/m²/°c) are a means of determining how well construction material can contain hear. For example a very well insulated wall will have a much lower U value than an un-insulated wall.

All applicable U Values must be completed (refer to guide for assistance)

Input the areas for inside walls, doors and windows if applicable otherwise leave these fields blank.

  Area (m²) U-value
W/m²/°C
Outside wall
Inside walls
Roof
Floor
Windows
Door m ²

Guide to typical U values (W/m²/°C)

External Walls
9" Sold Brick 2.2
11" Brick-block cavity (no insulation) 1.0
11" Brick-block cavity (insulated)) 0.6
Internal Walls
4.5" Brick/plaster 2.2
Plasterboard/ 4" studding/plasterboard 1.8
Floor
Solid concrete 0.8
Suspended timber 0.7
Roof
Corrugated asbestos 5.7
4" solid concrete 4.0
Flat roof 25mm insulation 0.9
Flat roof 50mm insulation 0.6
Glazing
Single glazing 5.6
Double glazing (air cavity) 2.8
Double glazing (argon gas cavity) 2.6
Double glazing low E glass (air cavity) 1.8
Double glazing low E glass (argon gas cavity) 1.5
Door
Timber 2.4
Insulated Roller Shutter 1.4
Un-insulated Roller Shutter 4.0

Stage 4 of 5 » Ventilation

Air changes per hour
(refer to guide for assistance)

The following figures apply to naturally ventilated buildings only. If a building has fan forced ventilation then the number of air changes per hour will be much higher.

Building Typical Air Changes per Hour
Shop 1
Office 0.9
School 0.7
Warehouse 0.5
Hall 0.8

Stage 5 of 5 » Total Heat Loss Calculation

Heat calculation based on the information you've given:

 

SWD

Downloads

Instructions and specification sheets are available for BN Thermic’s entire range of products, including SWD Industrial Finned Tubular Heaters.

SWD

Product Images

SWD - Industrial Tubular Heater

SWD - Industrial Tubular Heater

SWD - Industrial Tubular Heater with safety guard

SWD - Industrial Tubular Heater with safety guard

SWD - without thermostat

SWD - without thermostat

SWD - with built-in thermostat

SWD - with built-in thermostat

Installation Images

An SWD being used for frost-protection inside a container used for mobile energy supply

An SWD being used for frost-protection inside a container used for mobile energy supply

SWDs can be easily wall or floor mounted depending on your application

SWDs can be easily wall or floor mounted depending on your application

ENQUIRY FORM

Please provide as much information as possible

Industrial and Commercial Heating Enquiry Form

Please provide as much information as possible

Dimensions

m
m
m

Glazing

m2
m2
°C
°C

Underfloor Heating Enquiry Form

Please provide as much information as possible

Dimensions

Pipe freeze Protection Enquiry Form

Please provide as much information as possible