SMH-30 Main view - Mounted
Home > Fan assisted heaters > SMH Surface-Mount Ceiling Heaters

SMH Surface-Mount Ceiling Heaters

Print this tab
SMH-30 Main view - Mounted

SMH-30 Main view - Mounted

  • Low profile ceiling heaters allowing free use of floor and wall space
  • UK manufactured  high quality heater providing years of trouble-free service
  • Quick hassle free installation
  • Optional controller for variable outputs and fan only settings
SMH-30 Main view - Mounted

SMH-30 Main view - Mounted

SMH-30 Underside view

SMH-30 Underside view

SMH-30 Rear View showing mountings and connections

SMH-30 Rear View showing mountings and connections

SMH units can be easily suspended on chains or drop rods

SMH units can be easily suspended on chains or drop rods

SMHs creating a warm working environment in a London office

SMHs creating a warm working environment in a London office

Our SMH range can be surface mounted or installed on drop rods

Our SMH range can be surface mounted or installed on drop rods

Range

Basic Models

Model

kW

Volts

Built-in Thermostat

Airflow (m³/h)

SMH-30

3.0

230

No

220

SMH-45

4.5

230

No

330

SMH-60

6.0

230

No

490

       

 

Controls for Basic Models

Select controller and/or thermostat

Each heater can be controlled by one wall-mounted controller and/or one tamperproof thermostat

 

  Model Description
CS-7 Wall Mounted Controller

CS-7

Wall Mounted controller
RST-TP
RST-TP
Tamperproof thermostat 20A

 

Technical Specification

Colour:

White RAL9016

Finish:

Epoxy polyester powder coating

Construction:

0.9mm steel case

Fan Assembly:

Tangential fan with low noise aluminium fan blades
Shaded pole high performance motor
Factory lubricated bearings (servicing not required)

Heating Element:

High quality nickel-chrome resistance wire supported by ceramic plates and fitted with an automatically resetting over-temperature device

Control

Can be controlled by a wall-mounted CS-7 controller and/or a RST-TP tamperproof thermostat

Installation

Keyhole screw fixing to conventional ceiling or suspension from drop rods (4 x M8 threaded holes provided)

Recommended mounting heights 2.4m to 4m above floor level (see table below)

Guarantee

1 year

 

Performance Data

SMH Surface-Mount Ceiling Heaters (basic models)

Model

Volts

kW

Airflow (m³/h)

dB*@ 2m

Recommended Mounting Height (m)

SMH-30

230

3.0

245

56

2.4 – 3.0

SMH-45

230

4.5

345

60

3.0 – 4.0

SMH-60

230

6.0

490

58

2.4 – 3.0

         

*Noise levels are factory tested not laboratory tested

 

Physical data

Model

Width (mm)

Depth (mm)

Height (mm)

Weight (kg)

SMH-30

576

434

180

11.5

SMH-45

576

434

180

12.5

SMH-60

592

572

152

12.5

       

 

Spare Components

This is a list of the more frequently requested spare components.  Should you require a component that is not listed please contact BN Thermic.

Part Number

Description

AS-SCH-30

Fan/motor/element assembly (3kW) - two used in 6kW heater

AS-SCH-45

Fan/motor/element assembly (4.5kW)

Features and Benefits

Feature

Benefit

High level mounting

Allows free use of floor and wall space

Low profile compact design

Minimum visual impact

Keyhole screw fixing

Quick and easy installation

M8 threaded holes in top of case

Allows drop rod suspension if required

Auto-reset over-temperature device

A safety feature ensuring heater is switched off should air flow become obstructed

Optional wall mounted controller

Provides easy selection of on/off/high heat/low heat/fan only settings

Rear mounted terminal enclosures

Easy connection to power supply,  wall mounted controller and or thermostat

Removable brass links in terminal enclosure

Simple method of reducing heater output (3kW to 2kW, 4.5kW to 2.25kW and 6kW to 4kW)

Built-in electronic thermostat (SMH-30E only)

Accurate temperature control without the need for a wall mounted thermostat.  Note:  the fan will run continuously with the thermostat monitoring air temperature and adjusting the heater output accordingly

How it Works

SMH surface ceiling heaters provide comfort heat in commercial premises and are particularly well suited to shops.

Generally the heaters are mounted directly onto a conventional ceiling although they can be suspended from drop rods when required.  The powerful tangential fan draws in air from the space through the inlet which is heated by the heating element before being discharged back into the space.  This recycling approach ensures a rapid warm up.

 

Controls

There are three control options.  In all instances the control devices are connected to an easily accessible terminal enclosure.  Each heater will require dedicated control.  For multi-heater installations we recommend System X.

Remote Mounted Controller

The CS-7 controller should be wall-mounted in a convenient location providing the following settings.

  • On
  • Off
  • Low heat
  • High heat
  • Fan only

Remote Mounted Controller

The CS-1 controller can be used with all three basic SMH models.

Remote Mounted Tamperproof Thermostat

The RST-TP wall-mounted thermostat will provide accurate temperature control. 

Remote Mounted Tamperproof Thermostat

The RST-TP’s tamperproof design prevents casual adjustment of the temperature setting.

Combination of Remote Mounted Controller and Tamperproof Thermostat

This combination of control devices provides both manual and accurate thermostatic control.

The CS-7 controller should be wall-mounted in a convenient location providing the following settings.

  • On
  • Off
  • Low heat
  • High heat
  • Fan only

Combination of Remote Mounted Controller and Tamperproof Thermostat

The CS-7 controller can be used with all three basic SMH models

The RST-TP wall-mounted thermostat will provide accurate temperature control. 

Selection

If you would like the experts at BN Thermic to select a suitable heating for your application, please click below to access our enquiry form.  Simply provide as much information as you have available and we will respond with a detailed proposal.

ENQURY FORM

In simple terms the output of the SMH heater or heaters must be greater than the heat losses from the building during periods of cold weather.  A small amount of heat is lost through the walls, ceilings and floors with more significant losses through windows and doors.

To estimate the heat loss from your building you may like to use our heat calculation tool

HEAT CALCULATOR

The estimated heat loss figure is the absolute minimum kW output that you should consider installing.  We would suggest adding approximately 50% to this figure to allow for an acceptable warm up time in cold conditions as well as making allowances for exceptional weather conditions and possible errors in the original data used in the estimate.

Having established the minimum kW output, select the minimum number of heaters needed to meet this requirement.

Model

kW

Voltage

Recommended Mounting Height (m)

SMH-30

3.0

230

2.4 to 3.0

SHM-45

4.5

230

3.0 to 4.0

SHM-60

6.0

230

2.4 to 3.0

     

See the control section for choice of control components to complete the SMH system.

Heat Calculator

Stage 1 of 5 » Building dimensions

This calculator is provided as a quick and easy means of estimating heat loss from a building. This is a key step in determining the kW output required from a heating system.

Width m
Length m
Height m
Building dimensions

( * ) this data is compulsory

next >>>

Stage 2 of 5 » Environmental Data

Minimum outdoor temperature
(Typically -5°c in the UK)
°C
Required indoor temperature
(Typically 20°c in commercial buildings)
°C
Minimum temperature in the next room
(Input temp only if there is an adjoining room)
°C

Heat losses to an adjoining room or building are usually lower than to the outside world. To allow the calculator to take this into account we have requested the minimum expected air temperatures of an adjoining room. For a stand-along building just leave this field blank.

( * ) this data is compulsory

<<< back next >>>

Stage 3 of 5 » Construction material

U values (W/m²/°c) are a means of determining how well construction material can contain hear. For example a very well insulated wall will have a much lower U value than an un-insulated wall.

All applicable U Values must be completed (refer to guide for assistance)

Input the areas for inside walls, doors and windows if applicable otherwise leave these fields blank.

  Area (m²) U-value
W/m²/°C
Outside wall
Inside walls
Roof
Floor
Windows
Door m ²

Guide to typical U values (W/m²/°C)

External Walls
9" Sold Brick 2.2
11" Brick-block cavity (no insulation) 1.0
11" Brick-block cavity (insulated)) 0.6
Internal Walls
4.5" Brick/plaster 2.2
Plasterboard/ 4" studding/plasterboard 1.8
Floor
Solid concrete 0.8
Suspended timber 0.7
Roof
Corrugated asbestos 5.7
4" solid concrete 4.0
Flat roof 25mm insulation 0.9
Flat roof 50mm insulation 0.6
Glazing
Single glazing 5.6
Double glazing (air cavity) 2.8
Double glazing (argon gas cavity) 2.6
Double glazing low E glass (air cavity) 1.8
Double glazing low E glass (argon gas cavity) 1.5
Door
Timber 2.4
Insulated Roller Shutter 1.4
Un-insulated Roller Shutter 4.0

Stage 4 of 5 » Ventilation

Air changes per hour
(refer to guide for assistance)

The following figures apply to naturally ventilated buildings only. If a building has fan forced ventilation then the number of air changes per hour will be much higher.

Building Typical Air Changes per Hour
Shop 1
Office 0.9
School 0.7
Warehouse 0.5
Hall 0.8

Stage 5 of 5 » Total Heat Loss Calculation

Heat calculation based on the information you've given:

 

SMH

Downloads

Instructions and specification sheets are available for BN Thermic’s entire range of products, including SMH Surface-Mount Ceiling Heaters.

SMH

Product Images

SMH-30 Main view - Mounted

SMH-30 Main view - Mounted

SMH-30 Underside view

SMH-30 Underside view

SMH-30 Rear View showing mountings and connections

SMH-30 Rear View showing mountings and connections

Installation Images

SMH units can be easily suspended on chains or drop rods

SMH units can be easily suspended on chains or drop rods

An SMH-30 being used for frost protection in an industrial premises

An SMH-30 being used for frost protection in an industrial premises

SMHs creating a warm working environment in a London office

SMHs creating a warm working environment in a London office

Our SMH range can be surface mounted or installed on drop rods

Our SMH range can be surface mounted or installed on drop rods

ENQUIRY FORM

Please provide as much information as possible

Industrial and Commercial Heating Enquiry Form

Please provide as much information as possible

Dimensions

m
m
m

Glazing

m2
m2
°C
°C

Underfloor Heating Enquiry Form

Please provide as much information as possible

Dimensions

Pipe freeze Protection Enquiry Form

Please provide as much information as possible