PGE INSTALLED ON PIPES PRIOR TO INSULATING
.jpg)
pge-02
PGE
Pre-terminated pipe freeze protection cables
Application
A simple method of preventing water from freezing in metal or plastic pipes up to 40mm diameter assuming a minimum ambient temperature of -20°C. The pipe, cable and built-in thermostat should be covered with 13mm flame-retardant insulation.
PGE cables cannot be cut to length and must not be allowed to touch or cross.
Features
- Pre-terminated with 2m 3 core cold lead
- Built-in in-line thermostat energises the cable when temperatures fall below 3°C
- Metal earth braid running full length of the cable
- Fully moisture proof
Specification
| Model | Output (W) |
Volts | Heated Length (m) |
Weight (kg) |
|---|---|---|---|---|
| PGE-01 | 17 | 230 | 1 | 0.4 |
| PGE-02 | 35 | 230 | 2 | 0.5 |
| PGE-04 | 71 | 230 | 4 | 0.6 |
| PGE-08 | 117 | 230 | 8 | 0.8 |
| PGE-12 | 187 | 230 | 12 | 1.0 |
| PGE-14 | 230 | 230 | 14 | 1.1 |
| PGE-18 | 275 | 230 | 18 | 1.3 |
| PGE-24 | 373 | 230 | 24 | 1.5 |
| PGE-37 | 550 | 230 | 37 | 2.3 |
| PGE-49 | 735 | 230 | 49 | 3.0 |
Options
- Aluminium tape to be installed under the heating cable when applying to plastic pipes. The tape comes in a 45m roll and will dissipate the heat over the surface of the pipe Ref. AL-50
- Pack of 10 caution labels to be fitted to the outer cladding to warn of the presence of heating cable. Ref. 0010-007