OUH2 Industrial Fan Heater

System X
  • Provides an efficient means of heating industrial premises
  • Typical applications include warehouses and workshops
  • The most robust unit heater available offering exceptional reliability and backed by a 5 YEAR WARRANTY
  • Choice of seven models from 3kW to 25kW all with built in thermostat
  • Specially designed bracket for wall or ceiling mounting (heaters also suitable for suspension)
  • Multiple heaters can be controlled from a single point if required

Range & Prices

The prices shown are list prices and perfectly safe to use for budget purposes. Contact your electrical wholesaler for final prices.

10kW heater providing background heat in a storage facility in Kent

10kW heater providing background heat in a storage facility in Kent

Model Number kW Voltage List Price 
OUH2-03 3.0 230V or 400V/3N £662.00
OUH2-05 5.0 230V or 400V/3N £679.00
OUH2-07 7.5 230V or 400V/3N £689.00
OUH2-10 10 400V/3N £699.00
OUH2-15 15 400V/3N £1087.00
OUH2-20 20 400V/3N £1148.00
OUH2-25 25 400V/3N £1208.00

Optional Controller

Can be wall-mounted or fitted to the rear of a heater
Can control one heater or a chain of heaters.

Model Settings List Price
OUH2-S on/off/heat/fan only £50.00
OUH2 switch can be fitted to a heater. Can be wall mounted if preferred

OUH2 switch can be fitted to a heater. Can be wall mounted if preferred

Technical Specification

Colour: Light grey case with black grille and bracket
Finish: Epoxy polyester powder coating
Construction: 1.2mm steel case
Fan: Motor mounted in cool compartment
Thermally protected motor
Totally enclosed and factory lubricated fan motor
Protection Devices: High-limit temperature control with automatic reset
Heat purge device clears residual heat
Heating Element: Stainless steel sheathed tubular heating element
Concentric formation for optimum heat transfer
Control: Factory installed 230V fused control circuit
Factory installed contactor
Temperature control by means of factory fitted thermostat or choice of remote mounted thermostats.
Optional switch (OUH2-S) provides on/off/heat/fan only settings. Can be remote mounted or fitted to the rear of a heater
Built-in relays allow a group of heaters to be controlled by a single OUH2-S control switch,  thermostat or other controller
Installation: Specially designed bracket for ceiling or wall-mounting provides a variety of discharge angles and 360⁰ rotation
Suspension hooks are supplied as standard
Maximum recommended mounting height (3kW to 10kW): 2.5m (horizontal discharge), 3m (vertical discharge)
Maximum recommended mounting height (15kW to 25kW): 3m (horizontal discharge), 3.5m (vertical discharge)
Maximum operating ambient temperature:  30°C
Guarantee: 5 year (assuming standard comfort heating application)
OUH2 installed in a workshop in Billingshurst, West Sussex

OUH2 installed in a workshop in Billingshurst, West Sussex

Performance Data

Model   kW Volts Airflow (m³/h) Approximate Temperature
Rise (⁰C)
dB*@ 2m
OUH2-03 3.0 230/1 or 400V/3N 1100 7 60
OUH2-05 5.0 230/1 or 400V/3N 1100 13 60
OUH2-07 7.5 230/1 or 400V/3N 1100 19 60
OUH2-10 10 400V/3N 1100 25 60
OUH2-15 15 400V/3N 3150 13 65
OUH2-20 20 400V/3N 3150 17 65
OUH2-25 25 400V/3N 3150 22 65

* Noise levels are factory tested, not laboratory tested.

Physical Data

kW Height (mm) Width (mm) Depth (mm) Weight (kg)
3 to 10 320 435 405 18
15 to 25 445 565 485 37

Spare Components

This is a list of the more frequently requested spare components.  Should you require a component that is not listed please contact BN Thermic.

Part No Description Suitable For
40001 1kW Heating Element OUH2-03
40003 1.66kW  Heating Element OUH2-05
40004 2.5kW Heating Element OUH2-07
40002 3.3kW Heating Element OUH2-10
40005 5kW Heating Element OUH2-15
40006 6.66kW Heating Element OUH2-20
40007 8.33kW Heating Element OUH2-25
50030 Motor/Fan Assembly OUH2-03/05/07/10
50035 Motor/Fan Assembly OUH2-15/20/25
CON-32 Contactor OUH2-03/05/07/10
CON-50 Contactor OUH2-15/20/25
80150 Relay All models
80252 Heat Purge Device All models
80254 High Limit Device All models
80250 Factory Fitted Thermostat All models
OUH2 Unit heater suspended using hooks provided

OUH2 Unit heater suspended using hooks provided

OUH2 wall mounted in a warehouse in Axminster, Devon

OUH2 wall mounted in a warehouse in Axminster, Devon

Selection

If you would like the experts at BN Thermic to select a suitable heating for your application, please click here to access our enquiry form.  Simply provide as much information as you have available and we will respond with a detailed proposal.

Enquiry Form

In simple terms the output of the installed OUH2 industrial fan heater or heaters must be greater than the heat losses from the building during periods of cold weather.  A small amount of heat is lost through the walls, ceilings and floors with more significant losses through windows and doors.

To estimate the heat loss from your building you may like to use our heat loss tool

Heat Calculator

The estimated heat loss figure is the absolute minimum kW output that you should consider installing.  We would suggest adding approximately 50% to this figure to allow for an acceptable warm up time in cold conditions as well as making allowances for exceptional weather conditions and possible errors in the original data used in the estimate.

Once the target kW has been estimated it is generally as simple as selecting the minimum quantity of heater required to provide that output.  Select from the following table.

ModelkWVoltsAirflow  (m³/h)   
OUH2-033.0230V or 400V/3N1100
OUH2-055.0230V or 400V/3N1100
OUH2-077.5230V or 400V/3N1100
OUH2-1010400V/3N1100
OUH2-1515400V/3N3150
OUH2-2020400V/3N3150
OUH2-2525400V/3N3150

For perfect heat distribution the combined air volume flow rate of the selected heaters should also be considered.  Ideally the total air volume processed by the heaters every hour should be at least four times the total air volume in the building.  In some cases therefore, you may choose to select a larger number of lower output heaters in order to increase the total quantity of air processed every hour.

DSU

When using OUH2 industrial fan heaters in a building with a roof height in excess of 4m, the installation of a DSU destratification unit is strongly recommended.  This device will recycle warm air that has accumulated at high level thereby reducing heating bills by up to 30%.  It should also be noted that DSU destratification units provide very high air volume flow rates and often enable the ‘four times total air volume’ target to be achieved without needing to consider additional heaters.

DSU