Mats

Standard Output Mats (150W/m²)

Model

kW

Area (m²)

Size (m)

M150-005

0.07

0.5

1.0 x 0.5

M150-010

0.15

1.0

2.0 x 0.5

M150-015

0.22

1.5

3.0 x 0.5

M150-020

0.30

2.0

4.0 x 0.5

M150-025

0.37

2.5

5.0 x 0.5

M150-030

0.45

3.0

6.0 x 0.5

M150-035

0.52

3.5

7.0 x 0.5

M150-040

0.60

4.0

8.0 x 0.5

M150-045

0.67

4.5

9.0 x 0.5

M150-050

0.75

5.0

10 x 0.5

M150-060

0.90

6.0

12 x 0.5

M150-070

1.05

7.0

14 x 0.5

M150-080

1.20

8.0

16 x 0.5

M150-090

1.35

9.0

18 x 0.5

M150-100

1.50

10

20 x 0.5

M150-110

1.65

11

22 x 0.5

M150-120

1.80

12

24 x 0.5

M150-140

2.10

14

28 x 0.5

M150-160

2.40

16

32x 0.5

High Output Mats (200W/m²)

Model

kW

Area (m²)

Size (m)

M200-010

0.2

1.0

2.0 x 0.5

M200-015

0.3 1.5 3.0 x 0.5      

M200-020

0.4

2.0

4.0 x 0.5

M200-030

0.6

3.0

6.0 x 0.5

M200-040

0.8

4.0

8.0 x 0.5

M200-050

1.0

5.0

10 x 0.5

M200-060

1.2

6.0

12 x 0.5

M200-070

1.4

7.0

14 x 0.5

M200-080

1.6

8.0

16 x 0.5

M200-090

1.8

9.0

18 x 0.5

M200-100

2.0

10

20 x 0.5

Low Output Mats (100W/m²)

Model

kW

Area (m²)

Size (m)

M100-010

0.1

1.0

2.0 x 0.5

M100-015

0.15 1.5 3.0 x 0.5

M100-020

0.2

2.0

4.0 x 0.5

M100-030

0.3

3.0

6.0 x 0.5

M100-040

0.4

4.0

8.0 x 0.5

M100-050

0.5

5.0

10 x 0.5

M100-060

0.6

6.0

12 x 0.5

M100-070

0.7

7.0

14 x 0.5

M100-080

0.8

8.0

16 x 0.5

M100-090

0.9

9.0

18 x 0.5

M100-100

1.0

10

20 x 0.5

M100-120 1.2 12 24 x 0.5

Insulation

F-Board Insulation

Model

Thickness (mm)

Dimensions (mm)

Area per board (m²)

F-Board-6

6

1200 x 600

0.72

F-Board-10

10

1200 x 600

0.72

 

Accessories

Model

Description

EHM-R-Kit

Cable repair kit (emergency use only)

Floorprep

Primer for dust suppression and improved adhesion.  500ml (covers 6m² approx. diluted 1:1)

Floorroll

Roller for applying primer

Thermostats

Model

Operation

Max Load (A)

Max kW

Colour

T16CW

Programmable Touchscreen

16

3.6

White

T16CS

Programmable Touchscreen

16

3.6

Silver

T16CB

Programmable Touchscreen

16

3.6

Black

T16R

Optional remote air sensor for T16C range

U16C Programmable 15 3.4 White/Grey
A16C Manual Switching 15 3.4 White

Wireless Control

Model

Description

WSB-1

Relay Box  16A 3.6kW

WST-1

Wireless programmable thermostat (controls up to 4 relay boxes)

WSP-1

Programmable central programmer (controls up to 24 zones)

Contactors

Model

Amperage

Max kW (230V 1ph)

CON-32

32

7

CON-50

50

11.5

CON-80

80

18

ENCL-D

Enclosure for CON-32 and CON-50

Technical specification

Heating Mat Specification

Voltage supply: 230V
Outputs: from 0.07kW to 2kW depending on model
Webbing: fibreglass (500mm wide)
Fixing: continuous double sided tape
Power lead: 3m long two core and earth
Cable approvals: EN60335-2-96 as required by the 17th Edition Wiring Regulations (BS7671.2008)
Cable diameter: 3mm to 4mm
Earth screen: continuous AL/PET foil

F-Board Insulated Tile Backer Board Specification

Compressive strength (10% compression): 300kpa
Thermal conductivity to BSEN13164 (5 years): 0.033W/Mk
Water absorption by volume: 0.6%
Density (rigid foam core): 36kg/m³
Temperature range: -50°C to +75°C
U value (6mm thick board): 6.6W/m²k
U value (10mm thick board): 3.66W/m²k
Outer surface (top and bottom): Reinforced mesh with cementitious hard coat

Features & Benefits

Feature Benefit

Twin core heating cable                                                

Electrical connection on one end of the cable simplifying installation

Cable bonded to fibreglass web in evenly distributed loops

Ensures quickest possible installation time whilst maintaining an even heat distribution

Continuous earth foil

Avoids the risk of electric shock (for example when drilling into the floor)

3mm to 4mm cable diameter

Low profile installation keeps floor build-up to a minimum

3m pre-wired power lead which can be cut-back or extended

Flexibility of thermostat position

Continuous double sided tapes on the underside of the mat

Secure placement on any clean surface

Choice of output (150W/m², 200W/m² or 100W/m²)

150W/m² mats provides sufficient output for primary heating in almost every room.  200W/m² mats are ideally suited to conservatories and installations that require a quick warm up.  100W/m2 mats are frequently specified for properties with high levels of insulation.

Single mats up to 16m²

Most rooms can be heated with a single mat rather than a combination of mats

 

How it works

BN Thermic electric underfloor heating is installed above the existing sub-floor and underneath the selected floor surface turning the entire floor into a low temperature radiant heater. 

BN Thermic underfloor systems offer the following advantages over conventional heating systems such as radiators:

Heating distribution

Because the heating effect is spread over the entire floor area, the room is heated evenly.  Not only does this maximise levels of comfort but saves energy because it is not necessary to overheat some areas of a room to achieve an acceptable temperature in others.

No significant temperature gradient

With conventional convection based heating systems the temperature at high levels (i.e. above head height) is considerably higher than it is at low level.  As these higher temperatures have no benefit to the occupants of the room, the energy consumed in generating them is entirely wasted.  Underfloor heating is a radiant system which creates virtually no temperature gradient meaning that the temperatures at low level are the same as at high level.

No draughts or air currents

Conventional heating systems rely on air movement to warm a room.  This is not the case with an underfloor system resulting in the elimination of draughts.  This feature also eliminates the potential for the heating system to lift up dust and allergens making underfloor heating popular with asthma sufferers.

Low thermostat setting

The gentle radiant heating from an underfloor heating system will mean that people will experience a temperature slightly higher than the surrounding air temperature.  This effect means that thermostats can be set a few degrees lower than with the equivalent conventional system.

Every room individually controllable

With an electric underfloor heating system it is easy to programme every room to accurately reflect patterns of use.  The energy saving potential of this feature is considerable.

Does not use wall space

The elimination of radiators is the interior designer’s dream being particularly significant is apartments where space can be very limited.

Safety

An underfloor heating system operates at a very low temperature level completely eliniating the risk of burns even for the frail and elderly.

Controls

Thermostats

BN Thermic underfloor heating systems must be controlled by an approved thermostat.   All our thermostats are supplied with a floor probe (with plastic conduit) and have a built-in air sensor.  Primary temperature control can be by either the floor probe or the air sensor.

A16C Non-programmable thermostat

A16C

A16C      Non-programmable Thermostat

The A16C has a smart uncluttered appearance with a dial for temperature adjustment and an on/off switch.  The A16C can switch loads up to 3.4kW.

 

 

U16C Programmable thermostat

U16C

U16C      Programmable Thermostat

The U16C offers a simple 7-day programming with buttons hidden behind hinged doors on the thermostat face.  Features include a backlit screen and a summer switch allowing the heating to be switched off without losing the programme.  The U16C can switch loads up to 3.4kW.

 

T16CW Touchscreen thermostat - White

T16CW

T16CB Touchscreen thermostat - Black

T16CB

T16CS Touchscreen thermostat - Silver

T16CS

T16R Remote mounted wall sensor

T16R

T16C       Touchscreen Programmable Thermostat

The T16C is available with white, black or silver surrounds.  The thermostat provides ultra-simple 7-day programming as well as an energy use monitor.  When required, air temperature can be controlled by an IP65 rated, remote-mounted wall-sensor (T16R) which is suitable for bathroom installation.

The T16C can switch loads up to 3.6kW

Wireless Control

Different combinations of three standard control components provide a number of convenient wireless control systems for underfloor heating.

WSB-1 Relay Box

WSB-1

WSB-1 Relay Box

The WSB-1 relay box is generally mounted at low level and is suitable for installation in any room including bathrooms.  Each relay box is supplied with a floor probe and will control heating according to the wireless signals it receives from the WST-1 thermostat and/or the WSP-1 central programmer.

The WSB-1 can switch loads up to 3.6kW.

WST-1 Wireless thermostat

WST-1

WST-1 Wireless Thermostat

The WST-1 programmable thermostat is battery powered and can be wall-mounted or simply placed in a convenient location using the small stand provided.  The thermostat can send a signal to up to four WSB-1 relay boxes.

When used with the WSP-1 central programmer, the thermostats programmable functions are superseded and it will act primarily as a wireless air sensor although it will still provide a temporary override function

WSP-1 Central programmer

WSP-1

WSP-1   Central Programmer

The WSP-1 is a compact, touchscreen device providing individual programmable control for up to 24 heating zones.  Generally a heating zone would be an individual room. 

The combination of a single WSP-1 central programmer and the appropriate number of WST-1 thermostats and WSB-1 relay boxes will provide completely flexible control of every room in property from a one location.

Contactors

A suitably rated contactor allows a thermostat to control a larger load than its normal switching capacity. 

CON-32 with ENCL-D

CON-32 with ENCL-D

Model

Amperage

Max kW (230V 1ph)

CON-32

32

7

CON-50

50

11.5

CON-80

80

18

ENCL-D

Enclosure for CON-32 and CON-50

 

 

 

 

 

Selection

If you would like the experts at BN Thermic to select an underfloor heating system for you, please click below to access our enquiry form.  Simply provide as much information as you have available and we will respond with a detailed proposal.

ENQUIRY FORM

Selecting the required mat or mats for a room is a simple four step process.

Check floor surface

M Series heating mats are most commonly installed under tiles either in flexible self-levelling compound or directly into the tile adhesive.  However M Series heating mats are frequently used with other floor surfaces such as carpet, vinyl, laminate and engineered wood with the heating mat being completely covered in a flexible self-levelling compound which is allowed to dry before the floor surface is applied.

If there is any doubt about the suitability of any given floor surface for use with underfloor heating, confirmation should be sought from the flooring supplier.

Choose between standard output, high output or low output mat
Standard Output (150W/m²)

Other than in exceptional circumstances, standard output mats will provide a sole source of heat in a room

High Output (200W/m²)

High output mats should be selected when one of the following applies:

  • A room has exceptionally high heat losses (this may apply to some conservatories)
  • A rapid heat up is required perhaps because a room is rarely used
  • It is only possible to heat a small percentage of the total floor area
Low output (100W/m²)

Low output mats are often specified for properties with high levels of insulation.  The use of low output mats reduces the power demand for any given room and means that larger areas can be controlled by a single thermostat without the need of a contactor.

Select the correct size mat or mats

The objective is generally to cover as high a percentage of the free floor area as possible.  The free floor area is defined as the floor area not occupied by permanent fixtures such as kitchen cabinets and shower trays.  As a rule of thumb, we suggest selecting a mat with a total area approximately 10% less than the total free floor area.  This will allow for perimeter spacing and ensure easy installation.  In larger rooms it is common practice to install more than one mat.

A16C Non-programmable thermostat

Typical M Series Installation

 

Selection Table

Standard Output Mats (150W/m²)

Model

kW

Area (m²)

Size (m)

M150-005

0.07

0.5

1.0 x 0.5

M150-010

0.15

1.0

2.0 x 0.5

M150-015

0.22

1.5

3.0 x 0.5

M150-020

0.30

2.0

4.0 x 0.5

M150-025

0.37

2.5

5.0 x 0.5

M150-030

0.45

3.0

6.0 x 0.5

M150-035

0.52

3.5

7.0 x 0.5

M150-040

0.60

4.0

8.0 x 0.5

M150-045

0.67

4.5

9.0 x 0.5

M150-050

0.75

5.0

10 x 0.5

M150-060

0.90

6.0

12 x 0.5

M150-070

1.05

7.0

14 x 0.5

M150-080

1.20

8.0

16 x 0.5

M150-090

1.35

9.0

18 x 0.5

M150-100

1.50

10

20 x 0.5

M150-110

1.65

11

22 x 0.5

M150-120

1.80

12

24 x 0.5

M150-140

2.10

14

28 x 0.5

M150-160

2.40

16

32x 0.5

High Output Mats (200W/m²)

Model

kW

Area (m²)

Size (m)

M200-010

0.2

1.0

2.0 x 0.5

M200-015

0.3 1.5 3.0 x 0.5

M200-020

0.4

2.0

4.0 x 0.5

M200-030

0.6

3.0

6.0 x 0.5

M200-040

0.8

4.0

8.0 x 0.5

M200-050

1.0

5.0

10 x 0.5

M200-060

1.2

6.0

12 x 0.5

M200-070

1.4

7.0

14 x 0.5

M200-080

1.6

8.0

16 x 0.5

M200-090

1.8

9.0

18 x 0.5

M200-100

2.0

10

20 x 0.5

Low Output Mats (100W/m²)

Model

kW

Area (m²)

Size (m)

M100-010

0.1

1.0

2.0 x 0.5

M100-015

0.15 1.5 3.0 x 0.5

M100-020

0.2

2.0

4.0 x 0.5

M100-030

0.3

3.0

6.0 x 0.5

M100-040

0.4

4.0

8.0 x 0.5

M100-050

0.5

5.0

10 x 0.5

M100-060

0.6

6.0

12 x 0.5

M100-070

0.7

7.0

14 x 0.5

M100-080

0.8

8.0

16 x 0.5

M100-090

0.9

9.0

18 x 0.5

M100-100

1.0

10

20 x 0.5

M100-120 1.2 12 24 x 0.5
 

 

Select insulation boards
F-Board - two sizes

F-Board

To limit downward heat loss and to significantly improve economy, the use of F-Board insulated tile backer board is highly recommended.  The use of F-Board insulation is particularly important when heating mats are installed on top of an un-insulated concrete slab.  F-Board is available in two thicknesses: 6mm and 10mm.  We recommend using 10mm board except when it is vital to keep the floor height to a minimum.  Each board covers an area of 0.72m².  Therefore to select the correct number of boards, simply divide the total floor area by 0.72.

F-board is lightweight and easily cut to shape.

 

Selection table

F-Board Insulation

Model

Thickness (mm)

Dimensions (mm)

Area per board (m²)

F-Board-6

6

1200 x 600

0.72

F-Board-10

10

1200 x 600

0.72

M Series

Downloads

Instructions and specification sheets are available for BN Thermic’s entire range of products, including M Series Underfloor Heating Mats.

M Series

Product Images

M-Series Heating Mats

M-Series Heating Mats

BN Thermic F-Board thermal insulation boards are designed to go under M-Series mats.

BN Thermic F-Board thermal insulation boards are designed to go under M-Series mats.

We carry large stocks of F Series matting all available with next day delivery

We carry large stocks of F Series matting all available with next day delivery

Black touch screen thermostat

Black touch screen thermostat

Silver touch screen thermostat

Silver touch screen thermostat

White touch screen thermostat

White touch screen thermostat

Standard 7-day programmable thermostat

Standard 7-day programmable thermostat

Simple non-programmable thermostat with on/off switch

Simple non-programmable thermostat with on/off switch

Optional remote sensor

Optional remote sensor

Show more images

ENQUIRY FORM

Please provide as much information as possible

Industrial and Commercial Heating Enquiry Form

Please provide as much information as possible

Dimensions

m
m
m

Glazing

m2
m2
°C
°C

Underfloor Heating Enquiry Form

Please provide as much information as possible

Dimensions

Pipe freeze Protection Enquiry Form

Please provide as much information as possible