Model Number kW List Price
XH03 3.0 £1250.00
XH05 5.0 £1265.00
XH10 10 £1320.00
XH15 15 £1771.00
XH20 20 £1877.00
XH25 25 £1936.00

Control Components

Type Description Model

List Price

Controller With thermostat
On/off/high/low/fan only settings
Open window detection
CX1

£137.00

Controller With tamper resistant thermostat
On/off/high/low/fan only settings
Open window detection
CX2

£140.00

Controller Without thermostat
On/off/high/low/fan only settings
CX3

£139.00

Controller With digital programmable thermostat
Optimum start feature
CX6

£241.00

Controller For use with volt-free signal from BMS (for 230V signal a VI Interface is required) CX-BMS

£131.00

Sensor Optional remote sensor for use with CX1, CX2 or CX6 CXS

£39.00

Cable Cat5 terminated 5m DX05

£9.00

Cable Cat5 terminated 10m DX10

£14.50

Cable Cat5 terminated 20m DX20

£22.00

Joiner Cat5 cable joiner JX1

£5.00

Auxiliary Control Components

Type

Description

Model

List Price

Programmable Thermostat

Use with CX-3 for 7-day programmable control

Optimum start option

PROSTAT2

£115.00

Timer

7-day programmable timer for use with CX1 or CX2

PROTIM-7

£173.00

How it Works

System X industrial fan heaters provide comfort or background heat in a wide variety of industrial buildings such as warehouses and factories. 

A system will include a controller and up to 12 individual heaters.  The control daisy chain is connected using Cat5 cables ensuring the quickest possible installation time.  Power is introduced to each heater individually with the controller taking its power from the first heater in the chain.

A unique feature of System X is that any style of heater from the range can be incorporated into a control daisy chain.  For example, an air curtain could be added to an industrial fan heater system.  Heaters can be connected in any combination and any sequence.

Four industrial fan heaters controlled from a single controller

Four industrial fan heaters controlled from a single controller

Technical Specification

Colour: Light grey case with black grille and bracket
Finish: Epoxy polyester powder coating
Construction: 1.2mm steel case
Fan: Motor mounted in cool compartment
  Thermally protected motor
  Totally enclosed and factory lubricated fan motor
Protection Devices: High-limit temperature control with automatic reset
  Heat purge device clears residual heat
Heating Element: Stainless steel sheathed tubular heating element
  Concentric formation for optimum heat transfer
Control: Up to 12 heaters can be connected to a single controller in any combination or sequence.  Control connections are by Cat5 cable
Installation: Specially designed bracket, foe ceiling or wall mounting, provides a variety of discharge angles and 360﮿ rotation
  Suspension hooks are supplied as standard
Max air temperature:  30°C
Guarantee: 5 year (assuming standard comfort heating application)

Performance Data

Model kW Volts Airflow (m³/h) Approximate Temperature Rise ( ﮿C) dB*@2m

Max Recommended Mounting Height (m)

Horizontal Discharge Vertical Discharge
XH-03 3.0 230V/1 or 400V/3N 1100 7 60 2.5 3.0
XH-05 5.0 230V/1 or 400V/3N 1100 13 60 2.5 3.0
XH-10 10 400V/3N 1100 25 60 2.5 3.0
XH-15 15 400V/3N 3150 13 65 3.0 3.5
XH-20 20 400V/3N 3150 17 65 3.0 3.5
XH-25 25 400V/3N 3150 22 65 3.0 3.5

* Noise levels are factory tested, not laboratory tested.

Physical Data

kW Height (mm) Width (mm) Depth (mm) Weight (kg)
3 to 10 320 435 405 18
15 to 25 445 565 485 37
25kW heater providing comfort heat in a warehouse in Kent

25kW heater providing comfort heat in a warehouse in Kent

Technical Specifications – Controls

MODEL: CX1

Maximum number of heaters controlled: 12
Type of heaters controlled: any heaters from the System X range in any sequence
Electrical Supply: taken from heater via Cat5 cable
Heater settings: on/off/high heat/low heat/fan only
Built-in adjustable thermostat range: 0 to 30˚C
Connection to first heater in group: Cat5 cable
Mounting: surface mount
Dimensions: 120mm x 80mm x 40mm

Special Feature: Open window detection (user selectable)

CX1_01

Model: CX2

As CX1 but with a tamper resistant built-in thermostat

CX2_01

Model: CX3

As CX1 but without built-in thermostat or open window detection

CX2_01

Model: CX6

As CX1 but with:

7-day programmable timer
Temporary override
Temporary lock
Optimum start for enhanced economy (user selectable)

Without open window detection

PC-C1

Model: CX-BMS

As CX1 but without manual or thermostat control
Requires a volt-free signal from a BMS to switch heater on and off

Can operate with a 230V signal via a VI Interface

CX-BMS

Model: CXS

Remote mounted sensor for use with CX1, CX2 or CX6 controller
Overrides the controller’s built-in air sensor
Recommended maximum cable length between controller and sensor: 20m
Mounting: surface mount
Dimensions: 80mm x 80mm x 35mm

CXS Optional remote temperature sensor

Pre-terminated Cat5 Cables

DX05: 5m
DX10: 10m
DX20: 20m
JX1: Cat5 Joiner / Coupler – Click fit (Joins two Cat5 cables together should you require longer lengths)

Selection

If you would like the experts at BN Thermic to select a suitable heating for your application, please click here to access our enquiry form.  Simply provide as much information as you have available and we will respond with a detailed proposal.

Enquiry Form

In simple terms the combined output of the heaters must be greater than the heat losses from the building during periods of cold weather.  A small amount of heat is lost through the walls, ceilings and floors with more significant losses through windows and doors.

To estimate the heat loss from your building you may like to use our heat calculation tool

Heat Calculator

The estimated heat loss figure is the absolute minimum kW output that you should consider installing.  We would suggest adding approximately 50% to this figure to allow for an acceptable warm up time in cold conditions as well as making allowances for exceptional weather conditions and possible errors in the original data used in the estimate.

Having established the minimum kW output, select the minimum number of heaters needed to meet this requirement.   The heaters should be evenly distributed.

When ceiling heights exceed 4m, we strongly recommend the use of destratification units.  These devices will reduce heating costs by recycling warm air that has collected at high level.

Videos