- Provides central control for a group of halogen heaters
- Allows easy adjustment of heat intensity
- Control connections by Cat5 data cable for quick error-free installation
- Controller power provided through a Cat5 cable from the control box
Range & Prices
The prices shown are list prices and perfectly safe to use for budget purposes. Contact your electrical wholesaler for final prices.
Model | Description | List Price |
HC2 | Control box for up to six 3kW Heaters | £760.00 |
HC3 | Control box for up to four 4.5kW or 6kW Heaters | £760.00 |
HC-C1 | Controller | £146.00 |
HC-CRS | Controller – Rough Service IP66 | £153.00 |
HC-TMRS | Controller plus Run-down timer – Rough Service IP66 | £181.00 |
Ancillary System Components
Model | Description | List Price |
HC-B | Push button to activate run-down timer in HC-C1 | £59.00 |
FST-RS | Optional frost thermostat | £138.00 |
DX05 | Cat5 cable terminated 5m | £10.00 |
DX10 | Cat5 cable terminated 10m | £15.00 |
DX20 | Cat5 cable terminated 20m | £23.00 |
JX1 | Cat5 cable joiner | £5.50 |
Operation
A control box or a series of up to 10 control boxes is connected to a controller using a Cat5 data cable. Interconnection between control boxes is also by Cat5 data cable.
Halogen heaters are wired to the control box(es). The controller provides manual control of the halogen heaters enabling heat intensity to be adjusted.
The controller also has a built-in run-down timer that can be activated by an optional push button. Once the selected run-down period has elapsed, the heaters will be automatically switched off.
If required, a frost thermostat can be connected to each control box. This device will switch on the heaters if the air temperature drops to its set-point overriding the settings on the controller.
Controlling HN3-30 (3kW) Heaters each with 2 lamps
Each HC2 will control up to six heaters. The HC-C1 controller allows the heaters’ lamps to be switched individually meaning that outputs of 1.5kW or 3kW can be selected.
For larger installations up to 10 control boxes can be connected in a control daisy-chain with each controlling up to six heaters.
Note: this system cannot be used with linear heaters.
Controlling HN3-45 (4.5kW) or HN3-60 (6kW) Heaters each with 3 lamps
Each HC3 will control up to four heaters. The HC-C1 controller allows the heaters’ lamps to be switched individually meaning that outputs of ⅓, ⅔ or full power can be selected.
For larger installations up to 10 control boxes can be connected in a control daisy-chain with each controlling up to four heaters.
Technical Specification
Model | HC2 |
Description | Control box for 3kW (2 lamps) halogen heaters |
Heaters controlled |
HN3-30 3kW halogen heaters (6 max. per box) Not suitable for use with linear models Up to 10 control boxes can be linked using a Cat5 data cable and controlled from a single controller |
Controller Required | HC-C1 or HC-CRS or HC-TMRS |
Supply | 400V 3ph and neutral |
Dimensions | 280mm (w) x 320mm (high) x 80mm (deep) |
Weight | 3.6kg |
Features |
Optional frost protection by connecting FST-RS thermostat Soft start prolongs halogen lamp life |
Model | HC3 |
Description | Control box for 4.5kW or 6kW (3lamp) halogen heaters |
Heaters controlled |
HN3-45 4.5kW halogen heaters or HN3-60 6kW halogen heaters (4 max. per box) Up to 10 control boxes can be linked using Cat5 data cable and controlled from a single controller |
Controller Required | HC-C1 or HC-CRS or HC-TMRS |
Supply | 400V 3ph and neutral |
Dimensions | 280mm (w) x 320mm (high) x 80mm (deep) |
Weight | 3.6kg |
Features |
Optional frost protection by connecting FST-RS thermostat Soft start prolongs halogen lamp life |
Model | HC-C1 |
Description | Manual controller for use with HC2 and HC3 control boxes |
Settings (when used with HC2 control box) |
On/off/½ heat/full heat All heaters in a control group will function identically |
Settings (when used with HC3 control box) |
On/off/⅓ heat/⅔ heat/full heat All heaters in a control group will function identically |
Timer | Run-down timer programmable between 5 minutes and 2 hours Activated by optional HC-B push button |
Supply | Separate voltage supply not required Supply provided by the control box |
Dimensions | 120mm x 80mm x 40mm |
Weight | 0.1kg |
Model | HC-B | Description | Push button for use with HC-C1 controller | Function | Activates controller’s run-down timer (5 – 120 Minutes) | Supply | Separate voltage supply not required Supply provided by the controller |
Dimensions | 80mm x 80mm x 34mm | Weight | 0.1kg | Features | Connection to the controller via 150mm long pre-wired cable with 4-way plug Constant light indicates ‘heaters on’ The flashing light indicates the last minute of the operation |